Accupyc II
MODEL SELECTION
HARDWARE VERSATILITY
Sample Chamber Capacity
Sample Chamber Dimensions
Available MultiVolume Insert Kits
Temp Control Type
Catalog Number
AccuPyc II
MultiVolume Kits
1-cm ID x 1.1-cm D
134/00001/00
1 cm 3
0.1 cm 3
1.80-cm ID x 3.93-cm D
N/A
10 cm 3
1.0 and 3.5 cm 3
134/00000/00
A MultiVolume option allowing you to analyze smaller-sized samples with your current AccuPyc model is available for configurations listed below;
4.62-cm ID x 6.17-cm D
10 and 35 cm 3
134/00002/00
100 cm 3
Each kit includes appropriate insert(s), reference standard(s), and sample cup(s).
Bundle includes Control module and 2-ft cable connected to Analysis modules. AccuPyc II 1340 Remote Analysis Instruments
2000-cm 3 nominal cell volume 650- and 1300-cm 3 cups
1-cm ID x 1.1-cm D 1.80-cm ID x 3.93-cm D 4.62-cm ID x 6.17-cm D 5.84-cm ID x 13.94-cm D 9.7-cm ID x 26.00-cm D
134/00032/00 134/00033/00 134/00034/00 134/00031/00 134/00030/00
1 cm 3 10 cm 3
0.1 cm 3 1.0 and 3.5 cm 3 10 and 35 cm 3 NA 650 and 1300 cm 3
AccuPyc II Bundle
100-cm 3 nominal cell volume 10- and 35-cm 3 cups
N/A
100 cm 3 350 cm 3 2000 cm 3
1-cm 3 nominal cell volume 0.1-cm 3 cup 10-cm 3 nominal cell volume 1- and 3.5-cm 3 cups
Remote analysis modules only. Remote analysis units require connection to a control module or AccuPyc II 1340
Remote Analysis Module Only
1-cm ID x 1.1-cm D 1.80-cm ID x 3.93-cm D 4.62-cm ID x 6.17-cm D 5.84-cm ID x 13.94-cm D 9.7-cm ID x 26.00-cm D
1 cm 3 10 cm 3
134/00041/00 134/00040/00 134/00042/00
0.1 cm 3 1.0 and 3.5 cm 3 10 and 35 cm 3 NA 650 and 1300 cm 3
SOFTWARE VERSATILITY
100 cm 3 350 cm 3 2000 cm 3
N/A
Data Presentation
134/00043/00
Density vs Cycle # Average: 3.8691g/cm³ StandardDeviation: 0.0123 g/cm³
134/00046/00
The AccuPyc II can be operated with a keypad or an optional Windows ® interface that provides exceptional reporting and archiving capability. Both versions include direct sample mass input from a balance and cycle-based displacement volume reporting. With the Windows interface, features such as time-based pressure equilibration reporting and additional calculations such as percent solids content and total pore volume are included. Operational status can also be continually monitored in a status window on the monitor screen.
Density vsCycle#
3.895
Control Module Only
N/A N/A Control module only. Up to 5 analysis modules can be connected to a single control module. N/A N/A
3.890
3.885
134/00005/00
3.880
AccuPyc II 1340 Temperature -Controlled Instruments
3.875
Density (g/cm³)
3.870 Equilibration Report P2 (ExpansionPressure) shown every 1 second(s)
• Combined Report
1.80-cm ID x 3.93-cm D
134/00010/00
10 cm 3
1.0 and 3.5 cm 3
Use with External Recirculating Bath 15-50 ˚C
Cycle #1 Cycle #7
Cycle #2 Cycle #8
Cycle #3
Cycle #4
Cycle #5
Cycle #6
3.865
AccuPyc II TC
• Summary Report
134/00020/00
4.62-cm ID x 6.17-cm D
10 and 35 cm 3
18
100 cm 3
3.860
AccuPyc II TEC
CycleNumber 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 Vol. vs Cycle # Average: 6.3725 cm³ Standard Deviation: 0.0004 cm³
17
• User-Defined Tabular Reports
Vol. vs Cycle # Reference
134/00050/00
1.80-cm ID x 3.93-cm D
Sigma+/- Min/Max
Integral Thermo- Electric Cooling, 15-36 ˚C, ± 0.1 ˚C*
1.0 and 3.5 cm 3
10 cm 3
16
6.378
• Volume vs. Cycle #
15
134/00051/00
4.62-cm ID x 6.17-cm D
10 and 35 cm 3
100 cm 3
6.376
• Density vs. Time
14
FPO Cycle Number 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 22 24 26
6.374
• Total Pore Volume vs. Temperature
P2 (ExpansionPressure) (psig)
13
6.372
• Density vs. Cycle #
12
1.80-cm ID x 3.93-cm D
1.0 and 3.5 cm 3
134/00044/00 134/00045/00
10 cm 3
Use with External Recirculating Bath 15-50 ˚C
Volume (cm³)
6.370
11
• Options Report
4.62-cm ID x 6.17-cm D
0
2
4
6
8
10
12
14
16
18
20
10 and 35 cm 3
100 cm 3
Time (seconds)
6.368
• Equilibration Report
Research grade helium or nitrogen is strongly recommended. High purity Carbon dioxide, dry air, or argon may be used. A multigas option for up to four gases on one analysis unit is available.
6.366
• Sample Log
*Subject to environmental operating conditions
Made with FlippingBook